Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V
40W
3.33A
90-264Vac
76.2 x 50.8 x 23 mm
3.00” x 2.00” x 0.91”
0.08 kg (0.18 lb)
| Model | Description |
|---|---|
| MDS-040APS12 BA |
12V
40W
3.33A
90-264Vac
76.2 x 50.8 x 23 mm
3.00” x 2.00” x 0.91”
0.08 kg (0.18 lb)
| Model | Description |
|---|---|
| MDS-040APS12 BA |
|
Output Current
3.33A
|
|
Output Voltage
12V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
40W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5%
|
|
Load Regulation
± 1%
|
|
PARD
-
|
|
Start-up Time
3000ms @ 115Vac
|
|
Hold-up Time
15ms @ 115Vac
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 3% @ 50-100% load
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
22.8mV pk-pk @ Full load
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
90-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
0.85A @ 115Vac, 0.45A @ 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
86.5% (typ.)
|
|
Inrush Current
30A @ 115Vac, 60A @ 230Vac (typ.)
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
0.1mA @ 264Vac Normal Condition,
0.3mA @ 264Vac Single Fault Condition |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
-
|
|
|
Indicator
-
|
|
|
Cooling System
-
|
|
|
Input Terminal
JST 2P Connector: B2P3-VH(LF)(SN)
|
|
|
Output Terminal
JST 4P Connector: B4P-VH(LF)(SN)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.08 kg (0.18 lb)
|
Dimensions
76.2 x 50.8 x
23 mm
3.00” x 2.00” x 0.91” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-10°C to +50°C 100% load
50°C to 70°C de-rate power by 2.5% / °C |
|
Operating Humidity
10-95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50G 11ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
5-500Hz, 2.09Grms, 20 minutes for each three axis
|
|
Storage Humidity
-
|
|
Operating Altitude
3,000 meters (9842.52 feet)
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
150%, Latch Mode
|
|
Overload / Overcurrent
150%-210% of rated load current, Hiccup Mode, (Non-Latching, Auto Recovery)
|
|
Over Temperature
Hiccup Mode, (Non-Latching, Auto Recovery)
|
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with PE* connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 60950-1 (Ed.2,2005), IEC 62368-1
CCC GB 17625.1; GB 4943.1; GB/T 9254.1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
|
Medical Safety
IEC 60601-1 CB report
EN 60601-1, CAN/CSA-C22.2 NO. 60601-1, ANSI/AAMI ES 60601-1 |
|
Galvanic Isolation
Input to Output: 4000Vac
Input to Ground 1500Vac Output to Ground 500Vac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016,
Medical Devices Regulations 2002(UK MDR 2002) |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
IEC 60950-1, IEC 62368-1, CCC GB 17625.1; GB 4943.1; GB/T 9254.1
|
|
SIL3
-
|
|
Emission
EN/BS EN 55011, EN/BS EN 55032, FCC Title 47:Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC61000-3-2
|
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
48V
153.6W
3.2A
85-264Vac
24V
103.2W
4.3A
85-264Vac
18V
500.4W
0-27.8A
85-264 Vac
48V
153.6W
3.2A
85-264Vac